I. Daily Inspection (5 minutes daily)
1. Liquid Level Check: Confirm the liquid level in the dosing tank is above 1/3 to prevent the metering pump from running dry.
2. Sound Inspection: Listen to the metering pump to check for evenness and abnormal noises (such as harsh friction or vibration, which may indicate pump jamming or bearing wear).
3. Leakage Check: Observe pipe joints, valves, and the inlet and outlet of the metering pump for any dripping of liquid. If a leak is found, immediately tighten the joint or replace the seal.
4. Electrical Status: Touch the motor casing (avoid electric shock). If it feels excessively hot (above 60°C), stop the machine and check; check if the indicator lights on the control cabinet are normal (no flashing or alarm lights on).
II. Regular Cleaning (Perform according to frequency)
1. Dosing Tank Cleaning (Weekly): Drain the remaining liquid and rinse the inside of the tank with clean water.
If there are stubborn clumps, gently wipe them with a soft brush (avoid scratching the tank wall). 1. Dry the pipes thoroughly before adding new solution (corrosive solutions require cleaning with the corresponding neutralizing agent before rinsing).
2. Pipeline Flushing (once a month): Turn off the metering pump, open the valve at the end of the pipeline, and circulate clean water for 3-5 minutes to remove any residual solution from the pipeline.
III. Solution Management (To Prevent Deterioration and Reaction)
1. Accurate Concentration: Strictly follow the process requirements for solution preparation (e.g., 1% flocculant concentration = 1kg solution + 99kg water), and stir until completely dissolved.
2. Prevention of Deterioration: Volatile and easily precipitated solutions must be stored in sealed containers and stirred once daily (to prevent sedimentation and pipeline blockage).
3. Solution Replacement: When changing to a different type of solution, thoroughly clean the dosing tank, pipelines, and metering pump (rinse repeatedly with clean water at least 3 times) to prevent chemical reactions caused by mixing different solutions. IV. Parameter Monitoring (Ensuring Stable Operation)
1. Flow and Pressure: Record the metering pump's flow rate (e.g., 50 L/h) and outlet pressure (e.g., 0.3 MPa) daily. A sudden drop in flow may indicate a clogged filter or a stuck check valve.
V. Emergency Handling (Quick Resolution of Simple Faults)
1. Power Outage Shutdown: Immediately shut off the metering pump to prevent it from running dry after power is restored. After power is restored, check the liquid level before restarting.
2. Pipeline Blockage: Close the inlet and outlet valves, disassemble the blocked part, and flush with clean water or blow it through with compressed air (avoid using hard objects to clear the pipes).
3. Metering Pump Not Running: First check if the power is on and if the liquid level switch is working properly (a low liquid level will trigger pump shutdown), then check if the inlet and outlet valves are open.
VI. Other Common Problems
1. Air Bubble Alarm: Air bubbles in the pipeline or an empty solution bottle.
2. Low Battery Voltage Alarm: Insufficient battery power. 2. Drop count alarm: Infusion bottle empty, flow regulator not turned on, or sensor damaged.
VII. Maintenance Cycle Reference
1. Routine Maintenance: Perform flushing and sealing operations every 4 to 6 weeks to prevent catheter blockage and infection.
2. Long-term storage: If not used for more than 1 month, calibration and bubble/pressure alarm tests are required.