1. Dye Circulation System Malfunction
1. Clogged Nozzle or Obstructed Air Duct
Symptom: Reduced dye circulation efficiency, resulting in color shifts or fabric damage.
Cause: Dye particle accumulation or small air duct diameter (<200mm).
Solution: Clean the nozzle regularly to ensure a stable airflow pressure of 0.05-0.15 MPa.
2. Uneven Dye Concentration
Symptom: Significant color variation in the dyed fabric.
Cause: Insufficient dye circulation rate (<30L/min) or insufficient stirring.
Solution: Check the circulation pump and optimize dye distribution.
2. Abnormal Temperature Control
1. Excessive Temperature Fluctuation (>±1°C)
Symptom: Poor dyeing uniformity and reduced color fastness.
Cause: Sensor drift or aging of the heating element.
Solution: Calibrate the temperature sensor and replace any damaged heating elements.
2. Cooling System Failure
Symptom: The fabric feels stiff or shrinks after dyeing. Cause: Insufficient cooling water flow or valve malfunction. Solution: Check the cooling pipes and remove scale. 3. Mechanical Component Wear
1. Wear on the Fabric Lifting Roller or Fabric Guide Wheel
Symptoms: Fabric stalling and surface scratches.
Cause: Bearing wear or concentricity deviation.
Solution: Check key components quarterly and replace worn parts.
2. Deformed Overflow Pipe
Symptoms: Fabric accumulation or uneven dyeing.
Cause: Deformation caused by prolonged high temperatures or mechanical stress.
Solution: Replace the overflow pipe with corrosion-resistant material.
4. Automation System Failure
1. PLC Control Malfunction
Symptoms: Abnormal feeding, temperature adjustment, and other operations.
Cause: Interference with the I/O module or program error.
Solution: Check peripheral signals and reset the PLC program.
2. Sensor False Alarm
Symptoms: Abnormal liquid level or pressure display.
Cause: Probe contamination or short circuit.
Solution: Clean the sensor and test the signal circuit. V. Other Common Problems
1. Unstable Power Supply
Symptom: Frequent equipment restarts or shutdowns.
Cause: Voltage fluctuations (>±10%) or harmonic interference.
Solution: Install a stabilized power supply or UPS.
2. Deteriorated Seals
Symptom: Dye leakage or insufficient pressure in the dye vat.
Cause: Hardened seals due to long-term use.
Solution: Regularly replace acid- and alkali-resistant seals.