1. Head Cracking:
Cause: The primary cause of head cracking is the accumulation of chloride ions in the dye liquor on the inner surface of the head, leading to damage to the passivation film and pitting. Furthermore, internal operating stress and residual stress generated during cold working are also significant factors contributing to cracking.
Solution:
Select materials with better stress corrosion resistance, such as duplex stainless steel, and perform stress relief treatment after cold working.
Strictly control the chloride ion content in the dye liquor and avoid adding excessive amounts of dye accelerators such as sodium chlorite and salt.
Regularly clean the inner surface of the dyeing machine, especially the R area of the head, with water to reduce chloride ion accumulation.
2. Stress Concentration:
Cause: Stress concentration occurs in the large opening of the working door, which may affect the stability and service life of the equipment.
Solution:
Reduce stress concentration by optimizing the opening shape, size, and material selection.
Use finite element simulation for analysis and optimization.
3. Uneven Dyeing:
Cause: Uneven dyeing may be due to uneven dye liquor flow or improper steam nozzle design. Solution:
Optimize the design of the fabric guide tube and fabric guide head to ensure that the steam nozzle can evenly distribute the steam and liquid flow.
Use an external electrically adjustable nozzle to allow for correction and adjustment of the nozzle gap at any time.